国产精品一二三-国产精品一二区-国产精品夜夜爽张柏芝-国产精品夜色视频一级区-天堂俺去俺来也www久久婷婷-天堂va在线高清一区

Chinese

Advisory hotline: 4008-557-528

hot key words: Dongguan skived fin heat sink vendor Shenzhen skived fin heat sink vendor Dongguan PV inverter heat sink PV inverter heat sink vendor Jiangsu skived fin heat sink vendor Custom SVG heat pipe thermal module

Where you are:Home ? Solution ? Forced air cooling
Solution
Thermal management
Solution
Contact us >>>
Service Hotline:4008-557-528

Phone number:0769-86813888

Company Fax:0769-86813109

Company email:
po123@winsharethermal.com

Company address:Qingxi Town, Dongguan City, floating hill 418 Hong Mang Road

Forced air cooling is to enhance the air movement so as to realize the cooling approach that is required by the heat sources. There are two approaches to quickly realize better cooling performance and these include increasing the cooling surface area of the heat sources and increasing the air velocity when it flows through an object. The first approach of increasing the cooling surface area can be realized by installing heat sinks on the surface of the heat sources. Typically, a heat sink is firmly fixed on the heat source so as to obtain better cooling performance. The second approach of enhancing airflow can be realized by installing fans (wind turbines) to enhance ventilation and strengthen the cooling effect. Under most scenarios, adding a fan onto a heat sink can greatly enhance the cooling efficiency.
Forced air cooling is often used for the cooling of internal combustion engines. As we can see from the exterior of an internal combustion engine on a vehicle or motorcycle, there are fins and an exhaust guard for forced air cooling. The reason for the exterior fins is to increase the cooling area and the fan inside the exhaust guard is to enhance the airflow through the surface of the internal combustion engine so that the temperature of the engine can be reduced quickly to ensure normal operation.
In recent years, Winshare Thermal has been strengthening our research and development on the applications of forced air cooling techniques. We have realized our forced air cooling on wind power converters, PV inverters, and SVG high power machines. The cooling combination of high power skived fin heat sink + fans or high power skived fin heat sink + heat pipe can greatly enhanced the cooling performance.
Air cooling + extruded heat sinks
Air cooling +friction stir welded heat sinks
Air cooling +stitched fin heat sinks
Air cooling +skived fin heat sinks
Air cooling +heat pipe heat sinks
Design inputs, specifications and requirements:

Loss

Single loss
(W)

Number of devices

Total losses
(W)

Model number

Ambient temperatu
(℃)

Cooling design temperature(℃)

IGBT Module

426W

1

426W

FS150R12KT3

60

100

Grand total

 

 

426W

 

Schematic of PV inverter simulation model and cooling design parameters:
3pcs 6025 fans, 5mm to the front panel, the corresponding open area ratio on the panel is 65%, aluminum extruded heat sinks are used, Thermal interface material: 7762 grease 0.1mm, K=4W/m*K.
Descriptions of fan usage and parameters:
C6025M12BPLB1w-7 fan was used in the initial design
(Parameters: 12V, 4500RPM, 34.13dBA)
NMB2410ML-04W-B80 is used in our solution
(Parameters:12V, 7800RPM, 46dBA)

 
Schematic of the simulated temperature profile with the initial design fan:
Schematic of the simulated temperature profile with the new fan in our solution:
 
(Simulation results indicated that for the original heat sink with C6025 fan, the IGBT case temperature is 151℃. For our proposed solution with the NMB6025 fan, the IGBT casetemperature is 145℃. Both fans have the same fan speed, noise, voltage, life expectancy. Therefore, this NMB fan will be the first choice.)
Schematic of the simulation results of the air cooling solution for PV inverters and the summary of data:
Summary of data:
(1) This solution uses all aluminum skived fin heat sink with NMB6025ML 7800RPM fan. The heat sink profile and size remain unchanged. The base thickness remains unchanged. The fin thickness is 0.8mm with a total of 73fins and the gap is 2.3mm on the skived fin heat sink.
(2) Caution: It is required to adjust the fan location so that there is no gap between it and the front panel in an attempt to avoid air recirculation. (The original design has a 5mm gap, which causes air recirculation and the resulting temperature is 6℃ higher.)
(3) Simulation results: The IGBT case temperature is 94.2℃, which meets the customer requirement of 100℃ or below.

The voice of Winshare Thermal: credit and word

Winshare Thermal Ltd. (hereinafter referred to as Winshare Thermal) was founded in 2009. We specialize in the research and development, production and technical services of high power cooling solutions. We are devoted to becoming the leader in the thermal... [See details]

Copyright: Dongguan Winshare Thermal Ltd.

主站蜘蛛池模板: 91久久婷婷人人澡人人澡| 1024.1024亚洲 国产 图片| 欧美日韩精品国产一区在线| 欧美200z人禽交| 日b美女| 美女张开腿让男人桶爽免费看| 久久精品视频99| 麻麻乱妇伦伦小说正文| 日本三级3d漫画在线观看| 免费视频在线播放| 夜夜骑小说| 日韩亚洲欧美在线爱色| 人人插人人爱| 办公室高h荡肉呻吟孕妇| 又粗又长又大又黄的日本视频| 久久影院毛片一区二区| 男人cao女人| 久久无遮挡成人羞羞漫画| 日本高清一区二区三区水蜜桃| 摸逼逼综合网| 插妹妹导航| 农民工野外一级毛片| 一二三四视频中文字幕| 九九热九九| 老牛影院在线播放一区二区| 康熙微服第一部免费版第10集| 久久精品99| i9l传媒在线| 欧美拍拍视频| 一区二区三区不卡视频| 又粗又长又大又黄的日本视频| 逼逼爱鸡鸡| a级黄色毛片三个搞一| 欧美人伦禁忌dvd| 一个人看www在线视频资源| 久久99久久成人免费播放| 高清免费在线观看网址入口| 欧美一区二区三区久久综合| 九一制片厂果冻传媒麻豆杨柳| 尤蜜网站在线进入免费| 永久黄网站色视频免费观看99|